Product details
CAREvent® ALS Automatic Transport Resuscitator
The O-Two CAREvent® ALS handheld automatic transport resuscitator provide trained individuals with a safe and effective means of providing artificial ventilation during respiratory and/or cardiac arrest.
Product information
The O-Two CAREvent® ALS handheld automatic transport resuscitator provide trained individuals with a safe and effective means of providing artificial ventilation during respiratory and/or cardiac arrest.
These pneumatically powered, time/volume cycled resuscitators have the added feature of a manually actuated, automatic ventilation override button (manual button). The single slider control for the simultaneous adjustment of ventilation frequency and tidal volume has six, preset automatic and manual override settings for a range of patients from 20 kg body weight to large adults. An off position is provided so that they can be left attached to the gas supply with the supply turned on ready for immediate use. No electrical supply or batteries are required to operate the devices.
During mask-ventilated CPR, the first breath is delivered automatically followed by a manually actuated breath. This inhibits the automatic cycling for 20 seconds, allowing the rescuer to provide the 30 chest compressions recommended by the current guidelines for resuscitation. If the manual button is not depressed again the automatic cycling will re-start at the selected rate and volume.
Key features and details
- Each resuscitator comes equipped with a gurney clip that allows the resuscitator to be attached to the handrail of the hospital gurney or ambulance stretcher.
- The patient is protected from barotrauma due to over inflation by the audible, pressure relief system. This warns the operator of airway obstruction or airway restrictions. The excess delivered volume is discharged to atmosphere.
- The O-Two CAREvent® ALS handheld automatic transport resuscitator has the added advantage of synchronized intermittent mandatory ventilation (SIMV). This allows spontaneously breathing patients to demand breathe through the resuscitator on 100% oxygen, at their own desired rate and volume. Their inspiratory efforts will stop automatic cycling. Should the patient stop breathing, or their volume fall below the preset threshold the resuscitator will restart automatically at the selected rate and volume.
- Handheld, lightweight, portable, simple to use and extremely durable, the O-Two CAREvent® ALS handheld automatic transport resuscitators are specifically designed for the demands of the emergency resuscitation and rescue environment.
- Accessories available for the O-Two CAREvent® ALS handheld automatic transport resuscitator include standard and deluxe transport ventilator circuits with positive-end expiratory pressure (PEEP) ports.
- O‑Two CAREvent® ALS Automatic Transport Resuscitator (SKU 01CV3000) provides reliable, manual-free ventilation during resuscitation and transport. Designed for emergency settings, this handheld, oxygen-powered device delivers consistent tidal volumes (150–600 mL) at frequencies of 10–20 BPM, with a user-friendly slider to adjust for patient size.
Additional product specifications
Available models, sizes and options
Select the exact part number and package configuration shown below.
| SKU | Configuration / includes | Order |
|---|---|---|
| 01CV3000 | Model: With Gurney Clip, 6 Foot Supply Hose* and Universal Resuscitation Mask | Add to Cart |
| 01CV3100 | Model: With Gurney Clip, Adjustable 0-25 L/min Regulator with 2 DISS Self-Sealing Outlets, in Moulded Case with 6 Foot Supply Hose* & Universal Resuscitation Mask (Cylinder Not Included) | Add to Cart |
| 01CV3112 | Model: With Gurney Clip, Adjustable 0-25 L/min Regulator with 2 DISS Self-Sealing Outlets, Statvac® II Aspirator in Moulded Case with 6 Foot Supply Hose*, Yankauer Suction Tip with Tubing and Universal Resuscitation Mask (Cylinder Not Inclu | Add to Cart |
| 01CV3200 | Model: With Gurney Clip, Adjustable 0-25 L/min Regulator with 2 DISS Self-Sealing Outlets, in clamshell carrying case with 6 Foot Supply Hose* and Universal Resuscitation Mask (Cylinder Not Included) | Add to Cart |
| 01CV3212 | Model: With Gurney Clip, Adjustable, 0-25 L/min Regulator with 2 DISS Self-Sealing Outlets, 6 Foot Supply hose*, Statvac® II Aspirator in clamshell carrying case with Yankauer Suction Tip with Tubing and Universal Resuscitation Mask (Cylind | Add to Cart |
For purchasing, verify the exact SKU, packaging quantity and current availability. Cart links open in a new tab.
Compatible components and related equipment
The manufacturer lists the following part numbers in this equipment family. EMRN catalog matches are linked below; confirm the model and connection before ordering.
Instructions, PDFs and videos
Consult the official instructions for use before clinical operation. Resource links open in a new tab.
Frequently asked questions
What is CAREvent® ALS Automatic Transport Resuscitator?
The O-Two CAREvent® ALS handheld automatic transport resuscitator provide trained individuals with a safe and effective means of providing artificial ventilation during respiratory and/or cardiac arrest.
Which model or size should I order?
The available manufacturer/model SKUs are 01CV3000, 01CV3100, 01CV3112, 01CV3200, 01CV3212.
Where can I find instructions or technical documents?
Official O-Two manufacturer instructions and product-family resources are listed in Documents & Videos; use the model-specific manual whenever available.
Which replacement parts are listed for this equipment family?
O-Two lists 01FG6502, 01TA1852, 10-55330-CS, 17MP1535-CS, 17MP8690-CS, 17MP9039, 01PV1121 in the applicable manufacturer accessory family. See Compatible Parts for named EMRN product links. Match the device and connection before ordering.
Does this listing include other accessories?
Only the exact configuration stated in Models & Options should be assumed included. Accessories described under Compatible Parts may be sold separately.