The VR simulation features both one and two-handed operation of instruments such as metal and diamond burs of different sizes or suction.
Tempo – the temporal bone drilling simulation:
- Pre-defined training cases of middle ear with different anatomy and pathology
- Structures at risk such as facial nerve, tympanic chord, vestibular labyrinth, cochlea, auditory ossicles, carotid artery, sigmoid sinus and dura are highlighted
- Optional support function provides automatic alerts
- Predefined tasks such as exposure of sigmoid sinus, short process of the incus or facial nerve
- Permanent tracking of instrument movements
- Automatic skills assessment provides immediate and objective feedback of performance
- Automatic video capture of session provides additional insights
- Learning curves of individuals and groups help monitor and compare progress over time
- Upload own clinical or research data from CT or CBCT to create new specialized training cases
- System provides a bone model ready for drilling within minutes
- 3D anatomy may be further enhanced with structures at risk, identified using an advanced interactive segmentation approach
- Your cases can reach the same functionality as predefined training cases
- Allows for simultaneous handling of endoscope and a surgical instrument
- Provides straight and angular endoscopes and various instruments such as Blakesley forceps or debrider
- Structures at risk such as periorbita, optic nerve, optic chiasm, ethmoidal cells, olfactory bulb and internal carotid artery are highlighted
- Names of important landmarks such as the uncinate process are displayed when the endoscope is aimed at them
- Virtual surgical navigation system provides additional cross-sectional CT images
ENT Basic System | ENT Full System | Dental Full System | |
1022079 | 1022080 | 1022081 | |
Hardware | ‚úì | ‚úì | ‚úì |
Workstation computer
|
‚úì | ‚úì | ‚úì |
3D LCD Monitor
|
‚úì | ‚úì | ‚úì |
Two pairs of 3D glasses
|
‚úì | ‚úì | ‚úì |
Force feedback device (handle)
|
1 | 2 | 2 |
Space navigator
|
‚úì | ‚úì | ‚úì |
Foot pedal
|
‚úì | ‚úì | ‚úì |
Simulator housing with two arm rests and electrically adjustable height
|
– | ‚úì | ‚úì |
Software modules | |||
"Tempo" for temporal bone drilling exercises
|
‚úì | ‚úì | – |
"My Cases" for adding new simulations based on own CT or CBCT data
|
‚úì | ‚úì | – |
"Sinus" for endoscopic sinus surgery exercises
|
– | ‚úì | – |
Two-handed operation with bleeding and suction
|
– | ‚úì | – |
Documentation
Weight | 80 kg |
Dimensions | 100 x 70 x 130 cm |
Brand | Voxel-Man |