Cables to attach HeartStart AED to manikin defibrillation studs.
For Zoll Medical "Stat Padz™" hands-free cable a Defibrillator Connector # 05-10100 is required, as 05-10100 is discontinued, replacing items for training purpose only is item 185-50050 Physio/Mindray ShockLink Training Adapter;
For Physio-Control® Quik-Combo™ hands-free cable a defibrillator connector # 05-10000 is required, as 05-10000 is discontinued, replacing items for training purpose only is item 185-50450 Zoll ShockLink Training Adapter.
The Defibrillator Training Cable 151‑945006 is the official interface lead that joins your classroom defibrillator trainer (Corpuls, Zoll, LIFEPAK*, Philips*, etc.) to Laerdal manikins such as Resusci Anne, Resusci Junior, Little Anne AEDand QCPR models. By routing low‑energy training pulses and ECG markers through a shielded harness, it delivers realistic shock‑advisory, voice‑prompt and rhythm‑change scenarios—without exposing students to clinical‑level energy.
Why you need it
-
True‑to‑life AED workflow – learners power on, attach pads, analyse, and “deliver” a shock that the manikin instantly registers.
-
Universal trainer plug – works with most 2‑wire/3‑wire paddle or snap‑pad outputs (max 200 V pp training pulses).
-
Zero‑setup reliability – color‑coded ends and keyed couplers mean you cannot connect it wrong.
Key features & benefits
Feature | Training advantage |
---|---|
Shielded twisted pair core | Eliminates artefacts so rhythm analysis reacts exactly when pads attach. |
Locking mini‑DIN manikin plug | Snaps into Laerdal defib plate; won’t pull out mid‑scenario. |
Rugged TPU jacket | Flexible, tangle‑free, and alcohol‑wipe safe for infection control. |
2 m (6.5 ft) length | Plenty of reach from instructor table to manikin without excess slack. |
Built‑in current‑limit resistor | Protects internal electronics even if a full‑energy unit is accidentally connected. |
Ideal users
-
BLS / ACLS instructors running AED competency tests
-
Simulation centres integrating third‑party defib trainers with Laerdal manikins
-
EMS academies practising shock, CPR‑pause timing, and post‑shock rhythm checks
Specifications
Item | Detail |
---|---|
Part number | 151‑945006 |
Length | 2.0 m ± 0.05 m |
Manikin side | 6‑pin locking mini‑DIN (male) |
Trainer side | Dual 4 mm banana plugs + ECG sense clip (removable adapter set included) |
Max voltage | 200 V pp (training‑pulse only) |
Jacket | Grey TPU, Ø 5.5 mm |
Cleaning | Alcohol or quat wipe; do not autoclave |
Quick hookup
-
Insert the mini‑DIN into the manikin’s defib port until it clicks.
-
Attach banana plugs to the training defibrillator’s paddle output (red = apex, black = sternum).
-
Power on trainer, place pads or paddles on the manikin, and run your scenario.
-
Observe that the manikin announces “Shock delivered/Continue CPR” after each simulated discharge.
The Defibrillator Training Cable 151‑945006 ensures seamless communication between your AED trainer and Laerdal manikin—so every shock counts in building life‑saving confidence.
For use with
- Resusci®Anne CPR-D (Discontinued)
- SimMan®
- ALS Simulator (Discontinued)
- MegaCode Kelly™
- SimMan 3G
- MegaCode Kid
- SimJunior®
- Obstetric Solution – SimMom and MamaBirthie
- SimMan® 3G Trauma
- SimMan Vascular
- SimBaby Classic